Control Unit MNK2 for remote fuel dispensing control
Mechanical and electronic dispensers controller
The control unit MNK2 is used for remote control of both, mechanical dispensers (completed with shaft encoders) and dispensers equipped with electronic control (electronic
calculators).
|

|
|
Electronic Control Unit MNK2 for the fuel dispensing control |
Control unit functions
- simultaneous independent control of the two connected fuelling points
(nozzles),
- two-mode operation: prepay mode (total amount in currency units is set) or preset mode (volume in
liters is set),
- unit price setting in the functional mode of "Unit price setting" using the (*) and (ESC) keys of the control unit
keyboard,
- possibility of displaying the unit price for checking purposes while pressing the
(PRICE) key,
- blocking of the dispensing with zero unit price,
- computation of the total amount in currency units or the volume in
liters from the preset/prepay value and valid unit price after the dispensing preset value (volume in
liters) or the dispensing prepay value (total amount in currency units) has been set,
- recall of the last dispensing transaction values to repeat the transaction (a new dispensing of the same volume and total
amount),
- current display of the remaining total amount in currency units and volume in
liters with the simultaneous acoustic signaling of the current
dispensing,
- records and possibility of displaying of totals: the volume of product dispensed and the total amount of fuel dispensed independently for each of the two fuelling points
(nozzles),
- adding and possibility of displaying of the total volume of product dispensed and total amount of fuel dispensed during the shift independently for each of the two fuelling points
(nozzles),
- emergency stop of the dispensing from the control unit pressing the (STOP) key independently for each of the two fuelling points
(nozzles),
- stop of the dispensing automatically after the transaction preset/prepayed volume has been reached at the fuelling point
(nozzle),
- acoustic signaling and indication of no dispensing pulses detected within 15 seconds time period independently for each fuelling point
(nozzle),
- stop of the dispensing automatically after no dispensing pulses are detected within 30 seconds time period at the fuelling point (nozzle). The simultaneous indication of the fuelling point (nozzle) where such condition has been detected and the acoustic and optical
signaling of such
condition.
Basic technical data
| Number of fuelling points (nozzles) controlled simultaneously |
2 |
|
Accuracy of the volume counting in liters |
0.01 |
|
Unit price maximum in currency units |
9999 |
|
Accuracy of the unit price setting in currency units |
1 |
|
Volume preset maximum in liters |
9999 |
|
Volume preset accuracy in liters |
1 |
|
Prepay maximum in currency units |
99989900 |
|
Maximum power input in VA |
10 |
|
Dimensions in mm depending on the angle of display turn |
280x240x(35 to 85) |
|
Maximum weight in kg |
1.4 |
|
Power supply voltage |
230 V +10% -15%, 50 Hz |
| |
 |
| Block diagram of the Control Unit MNK2 connections to the dispenser |
|