Beta Control - control and information systems home 

 

 

CEMOL/LGM
GSM based Lift Remote Alarm System

CEMOL/LGM is the system designed for the lift remote alarm and the voice communication from a lift car to the service centre, according to the standard EN 81-28.
The device transfers the information on alarm situation via GSM network.

When a lift passenger pushes the ALARM button, CEMOL/LGM sends an SMS to an alarm centre or some other predefined relieving service. After the alarm message has been received in the alarm centre, it is acknowledged as the ALARM state and LED in the lift car starts to flash. To prevent unreasonable using of the ALARM button, it means in the non-emergency state, CEMOL/LGM monitors the error state of the lift continuously.

CEMOL/LGM sends the SMS regarding the activation, confirmation and ending of the emergency state. It also informs about power supply status, GSM credit, and the current lift state. On request we deliver the software application running in the service centre, which keeps a detailed record of the particular active CEMOL/LGM systems, based on the received SMS. The application monitors the function of the CEMOL/LGM systems, and establishes the voice phone call to a particular system if necessary.

CEMOL/LGM Remote Alarm System features:

  • pushing of the ALARM button activates the alarm system,

  • voice communication between the lift car and the alarm centre or the service person,

  • flashing LED signalises the successful connection to the alarm centre,

  • light indication acknowledges the receipt of the alarm in the service centre,

  • button for the deactivation of the ALARM state is installed (the deactivation of the ALARM is performed after the stacked persons have been relieved),

  • prevention of the unreasonable using of the ALARM button,

  • regular automatic checking of the system,

  • checking of the power supply,

  • automatic report on the GSM credit level,

  • optional voice communication to the lift machine room,

  • easy mounting to the standard DIN rail.

The lift remote alarm system, which part is HLASKA/LGM speakerphone, is available in two variants:

  • for one lift: CEMOL/LGM + speakerphone HLASKA/LGM,

  • for a pair of lifts sharing one machine room: CEMOL/LGM + 2 units HLASKA/LGM, see the block scheme.

The WEBMON lift remote alarm system, which we have developed and deliver, has been designed for serving up to eight lifts. WEBMON implements the monitoring of the lifts via Internet GSM/GPRS or Ethernet TCP/IP, see, please, more information in VTA/WEBMON/GSM/GD.

Basic technical data:

Power voltage +12V ±2V
Power consumption 50mA 
Power consumption during communication 110mA
GSM  900/1800MHz
Error Inputs from +40V to +50V
CEMOL/LGM dimensions 160x90x58mm (including the antenna 160x90x90mm)
HLASKA/LGM dimensions 130x65x30mm
Fixing dimensions for HLASKA/LGM

 57x122mm, diameter 4mm

Picture documentation